Package Include:
1 x Receiver: S6CA-DC-ANT3
1 x Transmitter: CD-6
1 x User manual
Application:
For long range wireless remote control DC and AC equipments, such as lamp, lights, LED lighting, motor, fan, pump, solenoid valves, door lock, heater, etc.
Feature:
Relay Output: This receiver is dry contact output, with three output terminals: NO, COM, NC, which serves as a switch. That means you should also connect a separate power supply to equipments.
With external antenna, the receiver has a farther working range.
The transmitter / remote can control the receiver from any place within a reliable working distance.
Wireless RF signal from the transmitter can pass through walls, floors, doors, or windows, but it will lose some operating range.
Receiver:
Model: S6CA-DC-ANT3
Operating Voltage: 12±1VDC (model S6CA-DC12), or 24±2VDC (model S6CA-DC24)
Output Type: Relay Output
Quiescent Current: ≤10mA
Maximum Load Current of Relay: 10A / channel
Channel: 6 CH
6 Selectable Working Modes: Self-locking, Momentary, Interlocking, Self-locking + Momentary, Momentary + Interlocking
Working Frequency: 433MHz
Operating Temperature: -20 °C ~ +70 °C
PCB size: 75 x 58 x 16 mm
Case size: 95 x 62 x 28 mm
Transmitter:
Model No.: 0021088 (CD-6)
Channel / Button: 6
Button Symbol:Â 1,2,3,4,5,6
Waterproof case, antenna and buttons, it can be used outdoors.
Operating Voltage: 9V (1 x 6F22-9V battery)
Operating Frequency: 433MHz
Modulation Mode: ASK
Transmitting Distance: 1km / 3000 ft (theoretically)
Unit Size: 150 x 50 x 30 mm
Matching Transmitters:
This receiver only works with the transmitter CD-6 .
Usage:
This receiver has three output terminals for each channel, "NC" for the NC terminal, "NO" for the NO terminal, and "COM" for the COM terminal.
Initial state of relay output terminals: Terminals “NO” and “COM” are Normally Open; Terminals “NC” and “COM” are Normally Closed.
Wiring:
1) If you want to control a DC 12V lamp, do as following:
1.1 Connect the positive pole of DC power supply to terminal <V+>, and connect the negative pole of DC power supply to terminal <V->.
1.2 Connect terminal <NO> to the positive pole of DC power supply, connect terminal <COM> to the positive pole of DC lamp, and connect the negative pole of DC lamp to the negative pole of DC power supply.
2) If you want to control an AC 220V lamp, do as following:
2.1 Connect the positive pole of DC power supply to terminal <V+>, and connect the negative pole of DC power supply to terminal <V->.
2.2 Connect terminal <NO> to the live wire of AC power supply, connect terminal <COM> to one side of AC lamp, and connect another side of AC lamp to the neutral wire of AC power supply.
Setting different working modes:
1) Setting Self-locking mode (operation with transmitter CD-6): When the receiver is in the learning status, press the button 1 on the transmitter.
Press the button 1 on the transmitter: The relay 1 in the receiver is activated, and the connected lamp 1 is turned on.
Press the button 1 again: The relay 1 is deactivated, and the connected lamp 1 is turned off.
............
Press the button 6 on the transmitter: The relay 6 in the receiver is activated, and the connected lamp 6 is turned on.
Press the button 6 again: The relay 6 is deactivated, and the connected lamp 6 is turned off.
2) Setting Momentary mode (operation with transmitter CD-6): When the receiver is in the learning status, press the button 2 on the transmitter.
Press and hold the button 1 on the transmitter: The relay 1 in the receiver is activated, and the connected lamp 1 is turned on.
Release the button 1: The relay 1 is deactivated, and the connected lamp 1 is turned off.
............
Press and hold the button 6 on the transmitter: The relay 6 in the receiver is activated, and the connected lamp 6 is turned on.
Release the button 6: The relay 6 is deactivated, and the connected lamp 6 is turned off.
3) Setting Interlocking mode (operation with transmitter CD-6): When the receiver is in the learning status, press the button 3 on the transmitter.
Press the button 1 on the transmitter: The relay 1 in the receiver is activated, and the connected lamp 1 is turned on. Other 5 relays are deactivated and other 5 connected lamps are turned off.
............
Press the button 6 on the transmitter: The relay 6 in the receiver is activated, and the connected lamp 6 is turned on. Other 5 relays are deactivated and other 5 connected lamps are turned off.
4) Setting Self-locking (Channels 1~3) + Momentary (Channels 4~6) mode: When the receiver is in the learning status, press the button 4 on the transmitter.
5) Setting Self-locking (Channel 1) + Momentary (Channels 2~6) mode: When the receiver is in the learning status, press the button 5 on the transmitter.
The operation with the transmitter CD-6:
6) Setting Momentary (Channels 1~2) + Interlocking (Channels 3~6) mode: When the receiver is in the learning status, press the button 6 on the transmitter.