1 Channel DC 10A Remote Control Switch Kit for 12V 24V Linear Actuator (Model: 0020317)

Regular price $49.00

Shipping calculated at checkout.

Package Include:
1 x Receiver: S1FC-DC12
1 x transmitter: CP-3
1 x User manual


Application:

This long distance 1 channel DC power 12V 24V wireless remote control switch kit with RF transmitter and radio receivers. For long range control the extension and retraction of electric linear actuator.
It can long range wireless control equipments with linear actuator, such as doors, windows, solar tracking system, medical devices, agricultural machinery, vehicles, ships, elevator platforms, lifting tables, TV lifts, robots, cabinetries, massage sofas, electric beds, medical chairs, etc.

Features:
Wireless control, easy to install.
Suitable for DC linear actuator.
DC 12~36V operating voltage range.
You can operate the linear actuator to extend or retract by using the buttons in the receiver or by the transmitter.
With three manual buttons: You can control the linear actuator by manual buttons.
With limit control terminals: You can connect sensors, limit switches or external devices to stop the linear actuator.
With wired control terminals: You can connect manual switches to control the linear actuator.
The transmitter / remote can control the receiver from any place within a reliable working distance.
The wireless RF signal from the transmitter can pass through walls, floors, doors, or windows, but it will lose some operating range.
The receiver has reverse power protection and over current protection built in.
The receiver only works with the selected transmitter which is matched to the receiver.
One or more transmitters / remotes can control one or several receivers simultaneously.
Two or more receivers may be used in the same area.

Receiver Parameters:
Model: S1FC-DC
Operating Voltage: 12~36 VDC
Output Voltage: 12~36 VDC same as input voltage
Working Frequency: 433.92 MHz
Channel: 1 CH, can work with 1 DC motor or 1 linear actuator
Quiescent Current: ≤6mA
Rated Current: 10A, so linear actuator or motor's maximum starting current cannot exceed 10A.
Wire range for the terminals: 22-14 AWG
2 Selectable Modes: Interlocking, Momentary
Operating Temperature: -20°C ~ +70°C
Case Size: 100 x 60 x 30 mm (4.0 x 2.4 x 1.2 inches)

Transmitter Parameters:
Model No.: CP-3
Channel/Button: 3
Button Symbol:▲, ■, ▼
Operating Voltage: 12V (1 x 23A -12V battery)
Standby current: 4uA
Operating Current: 14mA
Operating Frequency: 433Mhz
Transmitting Distance: 500m / 1500ft (theoretically)
Modulation Mode: ASK
Operating Temperature: -20 ° C to +70 ° C
Unit Size: 92mm x 40mm x 15mm

Matching Transmitters:
This receiver can work with different transmitters.
1) When you set the receiver in Momentary mode, it should work with two button transmitter, such as model C-2-2 (100 Meter / 300 feet) or CV-2-2 (500 Meter / 1500 feet).
2) When you set the receiver in Interlocking mode, it should work with three buttons transmitter, such as model C-3-2 (100 Meter / 300 feet), CP-3 (500 Meter / 1500 feet), or CB-3-2 (1000 Meter / 3000 feet).

Working Range:
With a transmitter (such as CP-3) to form a complete set, the maximum working distance can reach 500 meters in an open ground.
The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this maximum working distance.
If you want to have a further working range, you can install an external antenna to the receiver, and you also can use a powerful transmitter, such as CB series transmitters.

Setting different control modes:
1) Setting Interlocking mode: Short pins number 3 and 4 with a shouted cap.
The operation by the transmitter, such as CP-3:
Press the button ▲ on the transmitter: Linear actuator extends outward.
Press the button ▼ on the transmitter: Linear actuator inward retracts.
Press the button ■ on the transmitter: Linear actuator stops.

The operation by the receiver:
Press the button ▲ on the receiver: Linear actuator extends outward.
Press the button ▼ on the receiver: Linear actuator inward retracts.
Press the button ■ on the receiver: Linear actuator stops.

2) Setting Momentary mode: Short pins number 1 and 2 with a shouted cap.
The operation by the transmitter, such as CP-3:
Press and hold the button ▲ on the transmitter: Linear actuator extends outward.
Release the button ▲: Linear actuator stops.
Press and hold the button ▼ on the transmitter: Linear actuator inward retracts.
Release the button ▼: Linear actuator stops.

The operation by the receiver:
Press and hold the button ▲ on the receiver: Linear actuator extends outward.
Release the button ▲: Linear actuator stops.
Press and hold the button ▼ on the receiver: Linear actuator inward retracts.
Release the button ▼: Linear actuator stops.

Limit control terminals:
The receiver has limit control terminals, and you can connect external devices (with normally closed contact), such as sensors, limit switches to limit terminals, then use them to stop the motor or the linear actuator.
When linear actuator extends outward, if disconnect two terminals <TOPR> and <COM>, the linear actuator will stop automatically.
When linear actuator inward retracts, if disconnect two terminals <TOPL> and <COM>, the linear actuator will stop automatically.

Wired control terminals:
The receiver has wired control terminals, and you can connect external devices (with normally open contact), such as manual switches to wired control terminals, then use them to stop the linear actuator.
1) In Interlocking mode:
When connect two terminals <UP> and <COM>, the linear actuator extends outward. And when connect two terminals <STOP> and <COM>, linear actuator stops.
When connect two terminals <DOWN> and <COM>, the linear actuator inward retracts. And when connect two terminals <STOP> and <COM>, linear actuator stops.

2) In Momentary mode:
When connect two terminals <UP> and <COM>, the linear actuator extends outward. And when disconnect two terminals <UP> and <COM>, linear actuator stops.
When connect two terminals <DOWN> and <COM>, the linear actuator inward retracts. And when disconnect two terminals <DOWN> and <COM>, linear actuator stops.