Package Include:
1 x Receiver: S1XC-AC
1 x Transmitter: CB-1 or CB-2
1 x User manual
Application:
For long range remote control on and off AC electrical equipment, such as lamp, lights, LED lighting, motor, fan, pump, solenoid valves, door lock, heater, etc.
Feature:
Wireless control, easy to install.
Universal Power Supply: AC 85V~250V.
AC Power Output: It can control AC equipment with a voltage range of 85~250V AC (Such as AC devices with 110V, 120V, 220V, or 240V).
The transmitter / remote can control the receiver from any place within a reliable working distance.
The wireless RF signal from the transmitter can pass through walls, floors, doors or windows, but it will lose some operating range.
The receiver has reverse power protection and over current protection built in.
The receiver can only be triggered by paired transmitters.
Two or more receivers may be used in the same area.
One or more transmitters / remotes can control one or several receivers simultaneously.
Receiver Parameters:
Model: S1XC-AC
Operating Voltage: 85V~250V AC
Output Type: 85~250V AC (110V/120V/220V/240V), same as input voltage
Channel: 1 CH
3 Selectable Working Modes: Self-locking, Momentary, Interlocking
Static Current: ≤10mA
Maximum Load Current: 10A
Maximum Load Power: <2KW
Receiver Sensitivity: ≥-105dB
Working Frequency: 433.92MHz
Suitable Wires for Connecting Terminals: 22-16 AWG
Operating Temperature: -40°C ~ +80°C
PCB size: 76 x 34 x 18 mm
Case size: 98 x 40 x 23 mm
Transmitter Parameters:
Model No.: 0021023 (CB-1) / 0021024 (CB-2)
Channel/Button: 1 (CB-1) / 2 (CB-2)
Button Symbol: No symbol (CB-1) / A, B (CB-2)
Operating Voltage: 9V (1 x 6F22 -9V battery)
Operating Current: 30mA
Operating Frequency: 433.92MHz
Encoding Chip: PT2262 / PT2264 / SC2262
Transmitting Distance: 1000 meters / 3000ft (theoretically)
It has an on / off button on the side.
Modulation Mode: ASK
Operating Temperature: -20 ° C to +70 ° C
Unit Size: Unit Size: 135 x 42 x 25 mm
Applicable Transmitters:
The receiver can work with different transmitters.
When you set the receiver in Self-locking mode or Momentary mode, it should work with single button transmitter, such as model C-1 (100 meters / 300 feet range), CP-1 (500 meters / 1500 feet range), and CB-1 (1000 meters / 3000 feet range).
When you set the receiver in Interlocking mode, it should work with two buttons transmitter, such as model C-2 (100 meters / 300 feet range), CP-2 (500 meters / 1500 feet range), CD-2 (Industrial, 1000 meters / 3000 feet range), and CB-2 (1000 meters / 3000 feet range).
Working Range:
With a transmitter (such as CB-2) to form a complete set, the maximum working distance can reach 100 meters in an open ground.
The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this maximum working distance.
Usage:
The receiver can be used to control AC 85~250V (110V/120V/220V/240V) equipment.
Wiring:
1) Connect the live wire of AC power supply to terminal <L> of IN, and connect the neutral wire of AC power supply to terminal <N> of IN.
2) Connect the live wire of AC device to terminal <L> of OUT, and connect the neutral wire of AC device to terminal <N> of OUT.
Setting different control modes:
1) Setting Self-locking mode: Turn on the first bit of the dip switch.
The operation of Self-locking mode with the transmitter CB-1:
Press the button of the transmitter: The output terminals of the receiver outputs AC power, and the connected device is working.
Press the button again: The output terminals of the receiver stops outputting, and the connected device stopped working.
2) Setting Momentary mode: Turn off the first bit and the second bit of the dip switch.
The operation of Momentary mode with the transmitter CB-1:
Press and hold the button of the transmitter: The output terminals of the receiver outputs AC power, and the connected device is working.
Release the button: The output terminals of the receiver stops outputting, and the connected device stopped working.
3) Setting Interlocking mode: Turn on the second bit and turn off the first bit of the dip switch.
The operation of Interlocking mode with the transmitter CB-2:
Press the button A of the transmitter: The output terminals of the receiver outputs AC power, and the connected device is working.
Press the button B of the transmitter: The output terminals of the receiver stops outputting, and the connected device stopped working.