The information for electric linear actuator
This is an IP67 waterproof electric linear actuator J7 series, specially designed for cellar door scenarios. It only have a push function and no pull force design.
When the linear actuator is in the fully retracted state, if there is a power outage, the stroke rod can be manually pulled out or retracted to open or close the cellar door manually.
When the linear actuator is in the extended state, if there is a power outage, the linear actuator will remain stationary. The stroke rod can be manually pulled out to open the cellar door, but the stroke rod cannot be manually retracted to close the cellar door. You need to wait for the power to be restored before you can operate the linear actuator to retract to close the cellar door.
Key Features
New housing design, high working stability
Metal housing, able to work in very harsh environments
Metal gearbox, high strength wear-resistant gear
Aluminum alloy telescopic tube and outer tube, good corrosion resistant
Heavy duty design, high-power DC motor
Worm gear structure design, strong self-locking force
POM engineering plastic worm gear, low noise
Advanced waterproof and dustproof technology
With waterproof breather valve, ideal for use outdoors or in the rain.
Low power consumption and low noise
Built-in two limit switches, linear actuator will automatically stop when stroke rod reaches the limit position.
Technical Specifications
Working voltage: DC 12V
Stroke: 8~18 in (200~400 mm)
Optional speed: 5±1mm/s, 10±2mm/s
The above is the speed at no load, and the actual working speed will gradually slow down as the load increases.
Max load capacity: 3500N / 350 kg / 780 lbs at 5mm/s
Linear actuator can get maximum load capacity when it operates in the vertical direction, and the pulling force is less than pushing force.
No-load current: 0.5~1A at 12V
Full load current: 7A at 12V
Shaft diameter: 24mm
The diameter of the mounting holes for the front and rear connectors: 8mm [0.315 in]
Motor type: Brushed DC Motor
Duty cycle: 20%, max 5mins continuous use
Service life: approx. 25,000 cycles
Power cable: two-core wire
Cable length of the normal linear actuator: 1000±10%mm [40 in]
Certifications: CE
Environment temperature: -20℃ to 80℃
Operating noise: ≤45dB (Linear actuators with different parameters will have different noise levels.)
IP rating: IP67 (Ideal for use outdoors or in the rain, but it is not suitable for use submerged in water.)
|
Different no-load speeds and corresponding maximum thrust |
|||
| No-load Speed | Full load Speed | Maximum Thrust | Self-locking Force |
| 5mm/s | 3mm/s | 3500N / 350 kg / 780 lbs | 3500N / 350 kg / 780 lbs |
| 10mm/s | 5.5mm/s | 2500N / 250 kg / 560 lbs | 2500N / 250 kg / 560 lbs |
The Information For Wireless Remote Control Switch Kit
Application
For long range wireless remote control the extension and retraction of DC 12V electric linear actuator.
Feature
Wireless control, easy to install.
Suitable for DC linear actuator.
You can operate the linear actuator to extend or retract by the transmitter.
With limit control terminals: You can connect sensors, limit switches or external devices to stop the linear actuator.
With wired control terminals: You can connect manual switches to control the linear actuator.
The transmitter / remote can control the receiver from any place within a reliable working distance.
The wireless RF signal from the transmitter can pass through walls, floors, doors, or windows, but it will lose some operating range.
Receiver Parameters
Model: S1PF-DC12
Operating Voltage: 12±1VDC
Output Voltage: 12VDC
Channel: 1 CH, can work with 1 linear actuator
2 Selectable Modes: Interlocking, Momentary
Quiescent Current: ≤10mA
Rated Current: 40A, so linear actuator's maximum starting current cannot exceed 40A.
Working Frequency: 433MHz
Operating Temperature: -20°C ~ +70°C
Case size: 115 x 95 x 40 mm
Transmitter Parameters
Model No.: CP-3
Channel/Button: 3
Button Symbol:▲, ■, ▼
Operating Voltage: 12V (1 x 23A -12V battery)
Operating Frequency: 433MHz
Transmitting Distance: 500m / 1500ft (theoretically)
Modulation Mode: ASK
Unit Size: 92 x 40 x 15 mm
Working Range
With a transmitter (such as CP-3) to form a complete set, the maximum working distance can reach 500 meters in an open ground.
The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this maximum working distance.
If you want to have a further working range, you also can use a high power transmitter, such as CB-3-2 transmitter.
Wiring
1) Connect two wires of linear actuator to terminals “MOTOR” of the receiver, and you can exchange these two wires to change the moving direction of linear actuator.
2) Connect the positive pole of DC power supply to input terminal “+” of the receiver.
3) Connect the negative pole of DC power supply to input terminal “-” of the receiver.
Setting different working modes
1) Setting Interlocking mode: Turn the mode switch in the receiver to location L.
The operation by the transmitter, such as CP-3:
Press the button ▲ on the transmitter: Linear actuator extends outward.
Press the button ▼ on the transmitter: Linear actuator inward retracts.
Press the button ■ on the transmitter: Linear actuator stops.
2) Setting Momentary mode: Turn the mode switch in the receiver to location M.
The operation by the transmitter, such as CP-3:
Press and hold the button ▲ on the transmitter: Linear actuator extends outward.
Release the button ▲: Linear actuator stops.
Press and hold the button ▼ on the transmitter: Linear actuator inward retracts.
Release the button ▼: Linear actuator stops.
Limit control terminals
The receiver has limit control terminals, and you can connect external devices (with normally closed contact), such as sensors, limit switches to limit terminals, then use them to stop the linear actuator.
For example, you can connect a normally closed limit switch to terminals <COM> and <UP>, and connect another normally closed limit switch to terminals <COM> and <DOWN>.
When linear actuator extends outward, if disconnect two terminals <COM> and <UP>, the linear actuator will stop automatically.
When linear actuator inward retracts, if disconnect two terminals <COM> and <DOWN>, the linear actuator will stop automatically.
Wired control terminals
The receiver has wired control terminals, and you can connect external devices (with normally open contact), such as manual switches to wired control terminals, then use them to control the linear actuator.
For example, you can connect three manual switches to wired control terminals <S1>, <S2>, <STOP> and <GND> according to following wiring diagram.
1) In Interlocking mode: For example, connect 3 pushbutton manual switch (Model 0040024).
When pressing the UP button, two terminals <S1> and <GND> are connected, then the linear actuator extends outward. And when pressing the STOP button, two terminals <STOP> and <GND> are connected, then the linear actuator stops.
When pressing the DOWN button, two terminals <S2> and <GND> are connected, then the linear actuator inward retracts. And when pressing the STOP button, two terminals <STOP> and <GND> are connected, then the linear actuator stops.
2) In Momentary mode: For example, connect 2 pushbutton manual switch (Model 0040025).
When pressing and holding the UP button, two terminals <S1> and <GND> are connected, then the linear actuator extends outward. And when releasing the UP button, two terminals <S1> and <GND> are disconnected, then the linear actuator stops.
When pressing and holding the DOWN button, two terminals <S2> and <GND> are connected, then the linear actuator inward retracts. And when releasing the DOWN button, two terminals <S2> and <GND> are disconnected, then the linear actuator stops.